Connecting room control, energy and BMS to OPERA
Once room control is connected to OPERA, a room can switch to welcome mode (lights, AC, curtains) when the guest checks in and to energy-saving mode after checkout. When the guest presses “Do not disturb” or “Make up room”, that status can flow back to the hotel.
- Interface
- IFC8 FIAS
- Downstream
- Check-in
- Upstream
- Room status
Typical automations
| OPERA event | Room control action |
|---|---|
| Check-in | Welcome mode: lights on, AC to preset, curtains open, TV welcome page |
| Checkout | Energy mode: main loads off, AC to economy setpoint |
| Room move | Old room to energy mode, new room to welcome mode |
| VIP / language | Welcome page language, personal settings |
Implementation notes
- Room numbers and floor codes must match OPERA exactly (leading zeros included).
- Throttle status write-backs so OPERA logs don’t balloon.
- Design public areas separately; they usually shouldn’t depend on OPERA.
FAQ
Can room control send clean/dirty status back to OPERA?
Yes, FIAS supports room status sent from the third-party system. Whether write-back is allowed is up to housekeeping; many hotels only let housekeeping change room status in OPERA or their housekeeping system.