Link Control Records (LS / LA / LE / LD / LR)
After every connect, the third-party system must complete the handshake: identify itself, declare which records and fields it needs, then keep the link alive. An incomplete handshake is the most common cause of “connected but no data”.
- LS
- Link Start
- LD
- Link Description (version, interface type)
- LR
- Link Record
- LA
- Link Alive
- LE
- Link End
Typical handshake
3rd party → OPERA LS|DA261020|TI093000|
3rd party → OPERA LD|DA261020|TI093000|V#1.0|IF..|
3rd party → OPERA LR|RIGI|FLRNG#GNGAGD|
3rd party → OPERA LR|RIGO|FLRNG#|
3rd party → OPERA LA|DA261020|TI093000|
OPERA → 3rd party LS / LA ...
STX/ETX omitted.
IFis the interface type code; see the specification for values.
| Record | Common fields | Meaning |
|---|---|---|
| LS / LA / LE | DA TI | date, time |
| LD | DA TI V# IF | date, time, third-party version, interface type |
| LR | RI FL | RI record type wanted; FL concatenated field IDs |
Tips
- Send one
LRper record type you want. - Treat a long silence (no
LA) as a disconnect and reconnect. - Repeat the full handshake after every reconnect, and resync if needed.